Code: E510
Description: Paper transport jam (ADU section) Jam not reaching the ADU transfer sensor: The paper does not reach the ADU transfer sensor after it is switchbacked in the exit section.
Causes: ADU transfer sensor MAIN board Exit motor ADU exit sensor Rollers in the ADU Exit roller
Remedy: 1 Open the right cover. Is there any paper in front of the ADU transfer sensor? Yes Remove the paper. No 2 2 Is the ADU transfer sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[1]/ [C]) Yes 3 No • Check if the connector of the ADU transfer sensor is disconnected. • Check if the connector CN17 on the MAIN board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor patterns on the MAIN board are short circuited or open circuited. • Replace the ADU transfer sensor. • Replace the MAIN board. 3 Is the exit motor (rotating in reverse) working? (Perform the output check in the test mode: 03-121/ 171) Yes 4 No • Check if the connector of the exit motor is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Replace the exit motor. • Replace the MAIN board. 4 ADU • Check the rollers in the ADU and the exit roller of the equipment. Replace them if they are worn out.