Code: E743

Description: Jam not reaching the exit sensor (during reverse feeding): The original does not reach the exit sensor after it has passed the reverse sensor when the original is exited from the reverse section.
Remedy: Are the reverse roller and read roller stained? YES Clean the rollers. NO Is the exit sensor working? (Perform the input check: 03-[FAX]ON/[7]/[E]) NO 1) Check if the connector of the exit sensor is disconnected. 2) Check if the connector CN4 on the RADF board is disconnected. 3) Check if the connector pins are disconnected or the harnesses are open circuited. 4) Check if the conductor pattern on the RADF board is short circuited or open circuited. 5) Replace the exit sensor. 6) Replace the RADF board. YES Replace the RADF board.