Mã lỗi C411 — Toshiba e-Studio 2320c

Code: C411

Description: Thermistor or heater lamp abnormality at power-ON: Abnormality of the thermistor is detected when power is turned ON or the temperature of the fuser roller does not rise in a specified period of time after power is turned ON.
Causes: Power supply unit. LGC board
Remedy: Power voltage Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) Thermopiles • Check if the fuser belt center and side thermopiles (front, rear) are installed properly. • Check if the harnesses of the fuser belt center and side thermopiles (front, rear) are open circuited. Power supply unit and fuser unit • Is the fuser unit installed correctly? • Check if the heater lamp is broken. • Check if the connector of the heater lamp is disconnected. • Check if the thermostat is blown • Check if the connectors of the power supply unit are disconnected (power supply unit AC output connector CN408, CN409 and LGC I/F connector CN404 CN405). • Check if the power supply unit is abnormal. LGC board • Check if the connectors CN333, CN345 and CN361 are disconnected. • Check if the conductor pattern on the LGC board is short circuited or open circuited. Status counter After repairing the matter which caused the error [C411/C412], perform the following: • Turn ON the power while [0] and [8] are pressed simultaneously • Key in “2002”, then press [START]. • Change the current status counter value “1 “ or “2 “ to “0”, then press [OK] or [INTERRUPT] (to cancel [C411/C412]). • Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.

← Xem tất cả mã lỗi Toshiba e-Studio 2320c

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie