Code: C180
Description: LCF tray-up motor abnormality: The LCF tray-up motor is not rotating or the LCF tray is not moving normally.
Remedy: Does the tray move? (Perform the output check in the test mode: 03-271) NO 1) Check if the connector of the LCF tray-up motor is disconnected. 2) Check if any of the connectors CN100, CN101 and CN103 on the LCF board is disconnected. 3) Check if the connector CN310 on the LGC board is disconnected. 4) Check if the connector pins are disconnected and the harnesses are open circuited. 5) Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 6) Replace the LCF board. 7) Replace the LGC board. YES Are the LCF tray bottom sensor and LCF tray-up sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[5]/[F], /[3]/[A]) NO 1) Check if the connectors of the sensors are disconnected. 2) Check if any of the connectors CN100, CN104 and CN105 on the LCF board is disconnected. 3) Check if the connector CN310 on the LGC board is disconnected. 4) Check if the slit reaches the sensors. 5) Check if the connector pins are disconnected and the harnesses are open circuited. 6) Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 7) Replace the LCF board. 8) Replace the LGC board. YES 1) Check if the conductor pattern on the LGC board is short circuited or open circuited. 2) Replace the LGC board.