Code: E51
Description: Jam not reaching the ADU sensor: The paper does not reach the ADU sensor after is switchbacked the exit section.
Remedy: Open the ADU. there any paper front the ADU sensor?
YES Remove the paper. Is the ADU sensor working? (Perform the input check the test mode: 13-[04. SENSOR TEST])
NO 1) Check if either of the connectors CN251 on the ADU board is disconnected. 2) Check if the connector CN13 on the MAIN board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor patterns on the ADU board and MAIN board are short circuited or open circuited. 5) Replace the ADU board. 6) Replace the MAIN board.
YES Check the rollers the ADU. Replace them they are worn out.
YES Remove the paper. Is the ADU sensor working? (Perform the input check the test mode: 13-[04. SENSOR TEST])
NO 1) Check if either of the connectors CN251 on the ADU board is disconnected. 2) Check if the connector CN13 on the MAIN board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor patterns on the ADU board and MAIN board are short circuited or open circuited. 5) Replace the ADU board. 6) Replace the MAIN board.
YES Check the rollers the ADU. Replace them they are worn out.