Code: C43
Description: Fuser unit related service call. Thermistor abnormality during warming up or in ready status after abnormality judgment
Causes: MAIN board Switching regulator
Remedy: Check the thermistors • Check if the connectors are disconnected. • Check if the center, side and edge thermistors are in contact with the surface of the fuser roller properly. • Check if the harnesses of the center, side and edge thermistors are open circuited. Check the heater • Check if the heater is broken. • Check if the connector of the heater is disconnected. • Check if the thermostat is blown. Check the MAIN board • Check if the connectors CN17 are disconnected. • Check if the conductor pattern on the MAIN board is short circuited or open circuited. • Replace the MAIN board. Check the switching regulator • Check if the connectors CN108 are disconnected. Clear the status counter After repairing the matter which caused the error [C43], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in “400”, then press [START]. 3. Change the current status counter value “4” to “0”, then press [ENTER] or [INTERRUPT] (to cancel [C43]). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state