Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C04 — Toshiba e-Studio 245

Code: C04

Description: PFP motor abnormality: The PFP motor is not rotatingnormally.
Remedy: 1 Is the PFP motor working? (Perform the output check in the test mode: 04-109/159) Yes 2 No 1. Check if the signal line connector CN503 of the PFP motor is disconnected. 2. Check if the power line connector CN502 of the PFP motor is disconnected. 3. Check if the connector CN246 on the PFP board is disconnected. 4. Check if the signal line connector CN241 on the PFP board is disconnected. 5. Check if the power line connector CN242 on the PFP board is disconnected. 6. Check if the connector CN13 on the MAIN board is disconnected. 7. Check if the connector pins are disconnected and the harnesses are open circuited. 8. Check if the conductor patterns on the PFP motor board, PFP board and MAIN board are short circuited or open circuited. 9. Replace the PFP motor. 10. Replace the PFP board. 11. Replace the MAIN board. 2 Is the LED on the PFP motor board lit without flickering? Yes 3 No 1. Check if the connector pins are disconnected and the harnesses are open circuited. 2. Check if the conductor patterns on the PFP motor board, PFP board and MAIN board are short circuited or open circuited. 3. Replace the PFP motor. 4. Replace the PFP board. 5. Replace the MAIN board. 3 1. Check if the PLL lock signal CN246-8 output from the PFP board is always “L” level. 2. Check if the voltage supplied to the microcomputer input terminal IC5-17 is always “L” level. 3. Replace the PFP board. 4. Replace the MAIN board.

← Xem tất cả mã lỗi Toshiba e-Studio 245

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie