Code: C08

Description: ADU motor IC overcurrent detection error
Remedy: 1 Is the ADU motor working? (Perform the output check in the test mode: 04-110/160) Yes 2 No 1. Check if any of the connectors CN251 and CN252 on the ADU board is disconnected. 2. Check if the relay connector between the ADU board and the PFC board is disconnected. 3. Check if the connector CN246 on the PFC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the ADU board and the PFC board are short circuited or open circuited. 6. Replace the ADU motor. 7. Replace the ADU board. 8. Replace the PFC board. 2 Is the voltage supplied to the driver IC terminal IC1-18 on the ADU board is always at level "H"? Yes 3 No 1. Check if the voltage supplied to the connector CN251-12 on the ADU board is always at level "H". 2. Check if the voltage supplied to the connector CN246-6 on the PFC board is always at level "H". 3. Check if the voltage supplied to the CPU input terminal (IC4-96) on the PFC board is always at level "H". 4. Replace the PFC board. 3 Replace the ADU board.