Code: E11
Description: Paper misfeeding. ADU misfeeding (Paper not reaching the registration sensor): The paper which has passed through ADU does not reach the registration sensor during duplex printing.
Remedy: 1 Open the transfer cover. Is there any paper in front of the registration sensor? Yes Remove the paper. 2 No 2 Is the registration sensor working? (Perform the input check in the test mode: 13-[04. SENSOR TEST]) Yes 3 No 1. Check if the connector of the registration sensor is disconnected. 2. Check if the connector CN26 on the MAIN board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 5. Replace the registration sensor. 6. Replace the MAIN board. 3 Check the rollers in the ADU. Replace them if they are worn out.