Code: C140
Description: 2nd drawer tray abnormality
Causes: Tray-up motor PFU board LGC board Tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check: FS-03-243) Yes 2 No • Check if the connector of the tray-up motor is disconnected (CN922, J936). • Check if the connector on the PFU board is disconnected. (CN920, CN913) • Check if the connector on the LGC board is disconnected (CN368). • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 2 Is the tray-up sensor working? (Perform the input check: FS-03- [F3]ON/[4]/[E] Yes 3 No • Check if the connector of the sensor is disconnected (CN926, J933, J931). • Check if the connector on the PFU board is disconnected. (CN920, CN926) • Check if the connector on the LGC board is disconnected (CN368). • Check if the slit reaches the sensor. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 3 PFU board • Check if the conductor pattern on the PFU board is short circuited or open circuited. 4 LGC board • Check if the conductor pattern on the LGC board is short circuited or open circuited.