Mã lỗi CB50 — Toshiba e-Studio 2500AC

Code: CB50

Description: Stapler home position error * You receive a [CB50] error when the [EA50] error occurs three times in succession. Staple motor (M10) abnormality MJ-1042
Causes: Stapler motor (M10) Staple unit clinching home position sensor (S16) The staple unit clinching home position sensor (S16) does not detect the opening of the staple unit after the stapler motor (M10) has been driven reversely in the specified time from the closing during the initial movement of the staple unit. The staple unit clinching home position sensor (S16) does not detect the opening of the staple unit in the specified time from the closing during the clinching movement of the staple unit, and also this sensor does not detect the opening by the reverse rotation of the motor after the stapler is stopped. The staple unit clinching home position sensor (S16) does not detect the closing of the staple unit after the specified time during the clinching movement of the staple unit. The staple unit clinching home position sensor (S16) does not detect the opening of the staple unit at the start of the clinching.
Remedy: Staple motor (M10) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the staple unit. Staple unit clinching home position sensor (S16) abnormality Measure the voltage on CN16 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when the sensor is ON and within the range of 3.3V „bƒn5% when OFF. If the voltage does not fall within the range mentioned, replace the staple unit. Staple unit improper clinching prevention sensor (S15) abnormality Measure the voltage on TP25 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V „bƒn5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connectors. (Finisher control PC board (FIN): CN16, CN17) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the motor, sensors, switch and connectors, exchange the finisher control PC board (FIN).

← Xem tất cả mã lỗi Toshiba e-Studio 2500AC

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie