Mã lỗi E510 — Toshiba e-Studio 2500AC

Code: E510

Description: Paper transport jam (ADU section) Paper Jam in Automatic Duplexing Unit - Please Clear Paper Path. Paper not reaching the ADU entrance sensor jam
Causes: Feed or transport roller possibly causing multiple feeding Sensor in the jamming area Refer to the table below. LGC board
Remedy: 1 Jamming transport path Open the cover of the unit/area whose picture is flashing on the control panel and remove any paper on the transport path. 2 Feed or transport roller possibly causing multiple feeding Check the feed roller. 3 Sensor in the jamming area • Sensor check (Refer to the table below) • Harness check • Connector check 4 LGC board • Harness check • Connector check • Board check Notes: If the jam is occurring in the ADU, PFC, PFU, CFD, LCF or PFP, check the board in each unit.