Mã lỗi E120 — Toshiba e-Studio 2505

Code: E120

Description: Bypass misfeeding. Jam not reaching the registration sensor
Causes: MAIN board Bypass feed clutch Bypass paper sensor Bypass feed roller Separation pad
Remedy: 1 Open the right cover. Is there any paper on the transport path? Yes Remove the paper. No 2 2 Is the bypass feed clutch working? (Perform the output check in the test mode: 03-204) Is the bypass paper sensor working? (Perform the input check in the test mode: 03-[4]/[F]) Yes 3 No • Check if the connector of the bypass feed clutch and bypass paper sensor are disconnected. • Check if the connector CN22 on the MAIN board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor pattern on the MAIN board is short circuited or open circuited. • Replace the bypass feed clutch and bypass paper sensor. • Replace the MAIN board. 3 Bypass feed roller Bypass separation pad • Check the bypass feed roller and bypass separation pad. Replace them if they are worn out.