Code: E430
Description: Right cover opened during printing (When ADU is installed). Right cover open jam
Causes: Right cover opening/closing switch MAIN board
Remedy: 1 Is the right cover open? Yes Remove the paper if there is any, then close the right cover. No 2 2 Is the right cover opening/ closing switch working? (Perform the input check in the test mode: 03-[6]/ [A]) Yes 3 No • Check if the connector of the right cover opening/closing switch is disconnected. • Check if the connector CN25 on the MAIN board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor patterns on the MAIN board are short circuited or open circuited. • Replace the right cover opening/closing switch. 3 MAIN board • Replace the MAIN board.