Code: EA40
Description: [MJ-1042] Finisher cover open jam [MJ-1109/1110] Cover open error
Causes: MJ-1109/1110 Cover locking bracket If it is broken. Front cover switch (SW1) Stationary tray opening/closing switch (SW2) Finisher controller board (FIN)
Remedy: MJ-1042 Sub-path opening/closing sensor (S12) abnormality Measure the voltage on TP12 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V„b5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Front cover switch (SW1) abnormality Measure the voltage on TP77 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when the switch is ON and within the range of 3.3V„b5% when OFF. If the voltage does not fall within the range mentioned, replace the switch. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Finisher control PC board (FIN): CN10, CN13) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the switches, sensor and connector, exchange the finisher control PC board (FIN).
MJ-1109/1110 Cover • Close the front cover or the stationary tray if they are opened. Front cover switch (SW1) • Sensor check • Connector check • Harness check Stationary tray opening/closing switch (SW2) • Sensor check • Connector check • Harness check Finisher controller board • Connector check (CN14) • Board check
MJ-1109/1110 Cover • Close the front cover or the stationary tray if they are opened. Front cover switch (SW1) • Sensor check • Connector check • Harness check Stationary tray opening/closing switch (SW2) • Sensor check • Connector check • Harness check Finisher controller board • Connector check (CN14) • Board check