Code: C452
Description: Differential of more than 50°C between center thermistor and side thermistor when READY temperature is reached
Causes: MAIN board
Remedy: 1. Check the thermistors 1. Check if the connectors are disconnected. 2. Check if the center and edge thermistors are in contact with the surface of the fuser roller properly? 3. Check if the center and edge thermistors are not deformed or dirty. 4. Check if the harnesses of the center and edge thermistors are open circuited. 2. Check the MAIN board 1. Check if the connectors CN10 are disconnected. 2. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 3. Replace the MAIN board 3. Clear the status counter After repairing the matter which caused the error [C452], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in “2002”, then press [START]. 3. Change the current status counter value “62” to “0”, then press [OK] (to cancel [C452]). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.