Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C447 — Toshiba e-Studio 2505H

Code: C447

Description: Fixer temperature of 40°C or lower in READY state
Causes: MAIN board
Remedy: 1. Check the thermistors 1. Check if the connectors are disconnected. 2. Check if the center and edge thermistors are in contact with the surface of the fuser roller properly? 3. Check if the center and edge thermistors are not deformed or dirty. 4. Check if the harnesses of the center and edge thermistors are open circuited. 2. Check the heater 1. Check if the heater is broken. 2. Check if the connector of the heater is disconnected. 3. Check if the harnesses are connected properly to the terminals of the heater lamp. 4. Check if the thermostat is blown. 3. Check the MAIN board 1. Check if the connectors <25S: CN11, 25H/25F: CN10> are disconnected. 2. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 3. Replace the MAIN board 4. Check the power supply 1. Check if the connectors are disconnected. 2. Replace the switching regulator. 5. Clear the status counter After repairing the matter which caused the error [C447], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in “2002”, then press [START]. 3. Change the current status counter value “7”or “24” to “0”, then press [OK] (to cancel [C447]). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.

← Xem tất cả mã lỗi Toshiba e-Studio 2505H

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie