Code: C911
Description: Abnormal access between the CTRG board and MAIN board
Causes: Toner cartridge MAIN board HRNS-MAIN-PU-240 CTIF board
Remedy: 1 Does the recommended toner cartridge display appear when the toner supply cover is opened and closed? Use the recommended TOSHIBA toner cartridge. 2 Toner cartridge • Check the phenomenon by removing the toner cartridges and reinserting them. • Check that the CTRG board of the cartridge is installed properly. 3 Contact point on the equipment side Check that the spring of the contact point is not deformed. 4 Is the spring of the contact point returned when it is pushed lightly? • Check that the CTIF board is installed properly. • Board check 5 MAIN board • Connector check (CN16) • Board check 6 HRNS-MAIN-PU-240 • Connector check (CN16: Main board, CN150: CTIF board) • Harness check 7 CTIF board • Check that the board is installed properly. • Board check