Code: C010
Description: Main motor abnormality: The main motor is not rotating normally.
Causes: Main motor MAIN board
Remedy: 1 Is the main motor working? (Perform the output check in the test mode: 03-101/151) Yes 2 No 1. Check if the connector CN1 of the main motor is disconnected. 2. Check if the connector CN19 on the MAIN board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor patterns on the main motor board and MAIN board are short circuited or open circuited. 5. Replace the main motor. 2 Are there any damage or scratches on the main motor board? Yes 3 No 1. Check if the connector pins are disconnected and the harnesses are open circuited. 2. Check if the conductor patterns on the main motor board and MAIN board are short circuited or open circuited. 3. Replace the main motor. 3 MAIN board 1. Check if the PLL lock signal CN19-7 output from the MAIN board is always level "L"? 2. Replace the MAIN board.