Mã lỗi C260 — Toshiba e-Studio 2506

Code: C260

Description: Scanning system related service call Peak detection error: Lighting of the exposure lamp (white reference) is not detected when power is turned ON.
Causes: CIS harness CIS When replacing the CIS, be sure to perform the light volume adjustment (05-3219). MAIN board When replacing the board, be sure to perform the light volume adjustment (05-3219). Scan motor
Remedy: 1 Is the exposure lamp lit? Yes It is lit. 2 No It is not lit. 3 2 1. Shading correction plate 1. Check if there is any scratch or stain on the shading correction plate. 2. CIS 1. Perform the light volume adjustment (05-3219). 2. Check if the harness of the CIS is connected properly. 3. Check if the harness is scratched or open circuited. 3. MAIN board 1. Check if the harness of the MAIN board is connected properly. 2. Check if 3.3 V on the MAIN board is short circuited. 3. Check if 3.3 V is supplied to the MAIN board. 4. Check if the mounted parts on the MAIN board are damaged or abnormal. 4. Scan motor 1. Check if the belt tension is loosened. 2. Check if the harness of the motor is caught or open circuited. 3 1. CIS 1. Perform the light volume adjustment (05-3219). 2. Check if the harness of the CIS is connected properly. 3. Check if the harness is scratched or open circuited. 2. MAIN board 1. Check if the harness of the MAIN board is connected properly. 2. Check if 24 V on the MAIN board is short circuited. 3. Check if 24 V is supplied to the MAIN board. 4. Check if 3.3 V on the MAIN board is short circuited. 5. Check if 3.3 V is supplied to the MAIN board. 6. Check if the mounted parts on the MAIN board are damaged or abnormal.

← Xem tất cả mã lỗi Toshiba e-Studio 2506

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie