Code: F090
Description: Circuit related service call Memory abnormality on the MAIN board.
Causes: Memory (IC11) on the MAIN board.
Remedy: 1. Turn the power off, and start up the Setting Mode (08). 2. When "TEST MODE D" is displayed on the control panel, key in code: 9080 and press the [START] key. Notes: Code: 9080 cannot be keyed in except when 08-9010 is ON. To set the 08-9010, if this is the case, key in 08-9010- [START]- [CLEAR]- key in [1]- [OK]. 3. When "SELECT DESTINATION" is displayed, use the keys to select a direction and press the [OK] key. 4. When "MC=9080" is displayed on the control panel, press the [OK] key. To cancel, press the [CANCEL] key. 5. If SRAM clear ends normally, "INITIALIZE=OK" is displayed on the control panel, it automatically changes to the initial screen of the 08 mode. 6. Perform the initialization after the software version upgrade (08-9030). 7. Display the serial number (08-9601) and check the serial number. Key in the correct serial number using 08-9601 if the serial number is different from the serial number on the identification plate on the back cover. 8. Set the 08-9010 to "0". 9. Turn the power off and then on, if the error is not corrected, replace the SRAM on the main board.