Mã lỗi C411 — Toshiba e-Studio 2507

Code: C411

Description: Fuser unit related service call. Thermistor or heater lamp abnormality at power-ON: Abnormality of the thermistor is detected when power is turned ON or the temperature of the fuser roller does not rise in a specified period of time after power is turned ON
Causes: MAIN board Thermistors Heater lamp
Remedy: 1. Check the thermistors 1. Check if the connectors are disconnected. 2. Check if the center, side and edge thermistors are in contact with the surface of the fuser roller properly? 3. Check if the center, side and edge thermistors are not deformed or dirty. 4. Check if the harnesses of the center and edge thermistors are open circuited. 2. Check the heater 1. Check if the heater is broken. 2. Check if the connector of the heater is disconnected. 3. Check if the harnesses are connected properly to the terminals of the heater lamp. 4. Check if the thermostat is blown. 3. Check the MAIN board 1. Check if the connectors CN10 are disconnected. 2. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 3. Replace the MAIN board. 4. Clear the status counter After repairing the matter which caused the error [C411], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in “2002”, then press [START]. 3. Change the current status counter value “1” or “2” to “0”, then press [OK] (to cancel [C411]). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.

← Xem tất cả mã lỗi Toshiba e-Studio 2507

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie