Code: E510
Description: Jam not reaching the ADU entrance sensor: The paper does not reach the ADU entrance sensor after it is switchbacked in the exit section.
Causes: ADU entrance sensor LGC board Exit motor / Reverse motor Rollers in the ADU Exit roller
Remedy: 1 Open the ADU. Is there any paper in front of the ADU entrance sensor? Yes Remove the paper. No 2 2 Is the ADU entrance sensor working? (Perform the input check in the test mode: FS-03-[ALL]OFF/ [9]/[G]) Yes 3 No • Check if the connector of the ADU entrance sensor is disconnected. • Check if the connector CN321 on the LGC board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor patterns on the ADU board and LGC board are short circuited or open circuited. • Replace the ADU entrance sensor. • Replace the ADU board. • Replace the LGC board. 3 Is the exit motor / reverse motor (rotating in reverse) working? (Perform the output check in the test mode: FS-03- 121/171) Yes 4 No [20ppm/25ppm/30ppm] • Check if the connector of the exit motor is disconnected. (J609, J611) • Check if the connector CN324 on the LGC board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Replace the exit motor. • Replace the LGC board. [35ppm/45ppm/50ppm] • Check if the connector of the reverse motor is disconnected. (J609, J611) • Check if the connector CN307 on the LGC board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Replace the reverse motor. • Replace the LGC board. 4 ADU • Check the rollers in the ADU and the exit roller of the equipment. Replace them if they are worn out.