Description: Jam not reaching the original exit/reverse sensor (during scanning): The original which passed the read sensor does not reach the original exit/reverse sensor when it is transported from the scanning section to exit section.
Causes: Original exit/reverse sensor RADF board Read roller Replace it if it is worn out.
Remedy: Read roller Clean the read roller if it is stained. Original exit/reverse sensor • Sensor check (Perform the input check: 03-[FAX] ON[7]/[E]) • Connector check (J93) • Harness check RADF board • Board check • Connector check (CN75) • Harness check