Mã lỗi C440 — Toshiba e-Studio 255

Code: C440

Description: Heater abnormality after abnormality judgment: The temperature of the fuser roller has exceeded the range of control or does not even reach the range.
Remedy: 1,2.3. Check the thermistors, Heater and LGC board Check the above components following the procedures 1, 2 and 3 for [C410]. 4. Clear the status counter Change the current status counter value (08-400) “4” to “0” for [C430] and “5”, “7” or “9” to “0” for [C440], taking the same procedure as that for [C410]. * The status counter value is as follows in the following cases. Change them to “0” respectively. • The error occurred during warming-up: “4” or “5” • The error occurred after the equipment has become ready: “7” • The temperature detected by the center thermistor is 240°C or higher: “9” • The temperature detected by the side thermistor is 240°C or higher: “9” • The temperature detected by the edge thermistor is 240°C or higher: “9” only during printing.