Mã lỗi CCB0 — Toshiba e-Studio 255

Code: CCB0

Description: Alignment motor (rear) abnormality: The alignment motor (rear) is not rotating normally or the rear alignment plate is not moving normally. [MJ-1025] Offset motor abnormality: The offset motor is not rotating normally. [MJ-1031]
Remedy: MJ-1025 Is the aligning plate home position sensor (rear) (PI5) working properly? NO Replace the sensor. YES Is the wiring between the finisher controller PC board and aligning plate home position sensor (rear) correct? NO Correct the wiring. YES Is there any mechanical problem with the path of aligning plate? YES Fix the mechanism. NO Try replacing the alignment motor (rear) (M5). Is the problem corrected? YES End. NO Replace the finisher controller PC board.
MJ-1031 1. Check if the connector J104 on the finisher controller PC board is disconnected from the offset HP sensor (SR1) or the harnesses are open circuited. Correct if any. 2. Check if the connector J107 on the finisher controller PC board is disconnected from the offset motor (M5) or the harnesses are open circuited. Correct if any. 3. Replace the offset HP sensor. 4. Replace the offset motor. 5. Replace the finisher control PC board.