Code: C911
Description: Toner cartridge IC chip access board abnormality
Causes: Toner cartridge LGC board HRNS-LGC-TNRIC-212 CTIF board
Remedy: 1 Does non-genuine toner cartridge display appear when the front cover is opened and closed? Yes Use the genuine toner cartridge. No 2 2 Toner cartridge • Check the phenomenon by removing the toner cartridges (Y, M, C and K) and reinserting them. • Check that the CTRG board of each cartridge (Y, M, C and K) is installed properly. • Avoid touching the contact point. • Wipe the contact point with a soft cloth if it's stained. 3 Contact point on the equipment side Check that the spring of the contact point for each color (Y, M, C and K) is not deformed. 4 Is the spring of the contact point returned when it is pushed lightly? Yes No • Check that the CTIF board is installed properly. • Board check 7 Notes: The spring of the contact point may be released if you push the toner cartridge all the way in when an abnormality occurs. 5 LGC board • Connector check (CN375) • Board check 6 HRNS-LGC-TNRIC-212 • Connector check (CN375, CN440) • Harness check 7 CTIF board for each color (Y, M, C and K) • Check that the board is installed properly. • Board check