Code: CE80
Description: LED head communication error
Causes: LGC board Harness (FFC) Harness (power supply) LED head
Remedy: 1 Check the value of the selfdiagnosis code (08-4706) in which is displayed in the details of the LED head communication error. • Check each color with its corresponding self-diagnosis mode. Y: 08-4706-0 M: 08-4706-1 C: 08-4706-2 K: 08-4706-3 Remarks: The self-diagnosis value other than "0" (Normal) indicates that an error has occurred. Self-diagnosis values 1, 5, 9 and 13: LED head unconnected error 2 Self-diagnosis values 2, 6, 10 and 14: LED head mix error 4 Self-diagnosis values 4, 8 and 12: Checksum mismatch / Gradation module error 2 Self-diagnosis values other than the above 2 2 Is the LGC board normal? • Check the connectors used for the colors in which errors have occurred. Y: CN382 and CN383 M: CN380 and CN381 C: CN386 and CN387 K: CN384 and CN385 • Check the LGC board. 3 Check if the harnesses between the LGC board and the LED head are disconnected or open circuited. • Check the connectors and the harnesses used for the colors in which errors have occurred. <Harness (FFC) at the LGC board side> Y: CN382 M: CN380 C: CN386 K: CN384 <Harness (power supply) at the LGC board side> Y: CN383 M: CN381 C: CN387 K: CN385 <Harness (FFC) at the LED head side> Y: CN592 M: CN593 C: CN594 K: CN595 <Harness (power supply) at the LED head side> Y: CN596 M: CN597 C: CN598 K: CN599 Yes 4 No Repair it. 5 4 The LED head used for the colors in which errors have occurred. Repair it. 5 5 Reset the self-diagnosis value. Change the setting value of the LED head communication error details to "0" (Normal) to reset the self-diagnosis value. Y: 08-4706-0 M: 08-4706-1 C: 08-4706-2 K: 08-4706-3