Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C260 — Toshiba e-Studio 256

Code: C260

Description: Scanning system related service call Peak detection error: Lighting of the exposure lamp (white reference) is not detected when power is turned ON.
Causes: Lens unit SLG board Inverter / LED board Exposure lamp
Remedy: 1 Does the exposure lamp light? (Perform the output check: 03-267) Yes 2 No 3 2 CCD board SLG board 1. Check if the connectors on the CCD and SLG boards are disconnected. 2. Check if the shading correction plate is dirty. 3. Check if the conductor pattern on the CCD board is short circuited or open circuited. 4. Check if the conductor pattern on the SLG board is short circuited or open circuited. 3 Exposure lamp Inverter / LED board SLG board 1. Check if the connectors of the exposure lamp and inverter / LED board are disconnected. 2. Check the SLG board if the connector pin CN21 is disconnected or the harness is short circuited or open circuited. 3. Check if the conductor pattern on the SLG board is short circuited or open circuited.