Mã lỗi C49 — Toshiba e-Studio 28

Code: C49

Description: IH circuit or coil is abnormal
Remedy: 1. Check the IH control board (1) Check if the conductor pattern on the board is short or open-circuited. (2) Replace the IH control board. 2. Check the IH coil (1) Check if the coil is broken or shorted. (2) Replace the IH coil. 3. Clear the status counter Change the values “13”, “15”, “16” or “19” of the status counter (08-400) to “0”. * The status counter value is as follows in the following cases. Change them to "0" respectively. • The error occurred before the temperature of the fuser roller reaches 40°C: "13" • The error occurred before the temperature of the fuser roller reaches 150°C: "16" • The error occurred before the machine has become ready: "15" • The error occurred when the machine is in the ready state: "19" [C47], [C48] and [C49] can be cleared by turning OFF and ON the main switch as long as the problem was solved, and the status counter does not have to be changed to "0". The value of the status counter remains until the next service call overwrites the value.