Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi CCA0 — Toshiba e-Studio 281c

Code: CCA0

Description: Lower stack tray lift motor abnormality: The lower stack tray lift motor is not rotating or the lower stack tray is not moving normally. [MJ-1022]
Remedy: MJ-1022 Is the wiring between the finisher controller PC board and lower stack tray lift motor (M7) correct? → NO → Correct the wiring. YES Are the front and rear sides of the lower stack tray leveled? → NO → Level them. YES Is the lower stack tray lift motor clock sensor (S9) working properly? → NO → Replace the sensor. YES Is the stack tray paper height sensor (S10) working properly? → NO → Replace the sensor. YES Are the lower stack tray upper limit sensor (S13) and lower stack tray full sensor (S23) working properly? → NO → Replace the sensor or sensor controller PC board. YES Does the voltage between the pins J3-1 and -2 on the finisher controller PC board become 24V when the lower stack tray lift motor starts rotating? → NO → Replace the finisher controller PC board. YES Check the wiring between the upper stack tray lift motor and finisher controller PC board. If there is no problem, replace the motor.