Mã lỗi E713 — Toshiba e-Studio 281c

Code: E713

Description: Cover open jam in the read ready status: Jam caused by opening of the RADF jam access cover or front cover while the RADF is waiting for the scanning start signal from the equipment.
Remedy: Are the RADF jam access cover or front cover opened in read ready status? → YES → Close the cover NO Is the original excessively curled or folded? → YES → Flatten and set it again. NO Is the RADF jam access cover sensor working? (Perform the input check: 03-[FAX]ON/[7]/[C]) ↓→ NO → 1) Check if the connector of the RADF jam access cover sensor is disconnected. 2) Check if the connector CN75 on the RADF board is disconnected. 3) Check if the connector pins are disconnected or the harnesses are open circuited. 4) Check if the conductor pattern on the RADF board is short circuited or open circuited. 5) Replace the RADF jam access cover sensor. 6) Replace the RADF board. YES Replace the RADF board.