Description: Communication error between finisher unit and puncher unit: Communication error between the finisher controller PC board and punch controller PC board. [MJ-1025 (when MJ-6005 is installed)]
Remedy: MJ-1025 Is the problem solved by turning the power of the equipment OFF and ON? YES End. NO Is the wiring between the finisher controller PC board and the punch controller PC board correct? NO Correct the wiring. YES Measure the voltage between CN14-5 (+) and CN14-3 (-) on the finisher controller PC board 24 V? NO Replace the finisher controller PC board. YES Replace the punch controller PC board.