Mã lỗi E726 — Toshiba e-Studio 282

Code: E726

Description: Transport/exit signal reception jam: RADF receives the transport/exit reception signal from the equipment when no original is at the exposure waiting position.
Remedy: (1) If the original remains in the RADF, remove it. (2) If any paper remains in the equipment, remove it. (3) Turn the power OFF and then back ON. If the jam still occurs, lead the following procedure. (4) Check the connection between the RADF board and SLG board, and the connection between the RADF board and switching power supply. • Are the connection of the connectors and joint connectors normal? • Are the connector pins disconnected or are the harnesses open circuited? (5) Check if the 24V and 5V outputs of the switching power supply are normal. (6) Check if the conductor pattern on the RADF board is short circuited or open circuited. (7) Replace the RADF board. (8) Check if the conductor pattern on the SLG board is short circuited or open circuited. (9) Replace the SLG board.