Description: 1st drawer tray abnormality: The tray-up motor is not rotating or the 1st drawer tray is not moving normally. (the case that paper can be fed from any drawer except the 1st drawer)
Causes: Tray-up motor LGC board Tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check: 03-242, 243) Yes 2 No • Check if the connector of the tray-up motor is disconnected. • Check if the connector CN348 on the LGC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 2 Is the tray-up sensor working? (Perform the input check: 03-[ALL]OFF/ [4]/[B], /[4]/[A]) Yes 3 No • Check if the connector of the sensor is disconnected. • Check if the connector CN348 on the LGC board is disconnected. • Check if the slit reaches the sensor. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 3 LGC board • Check if the conductor pattern on the LGC board is short circuited or open circuited.