Description: Peak detection error: Lighting of the exposure lamp (white reference) is not detected when power is turned ON.
Causes: Lens unit SLG board Inverter Exposure lamp
Remedy: 1 Does the exposure lamp light? (Perform the output check: 03-267) Yes 2 No 3 2 CCD board SLG board • Check if the connectors on the CCD and SLG boards are disconnected. • Check if the shading correction plate is dirty. • Check if the conductor pattern on the CCD board is short circuited or open circuited. • Check if the conductor pattern on the SLG board is short circuited or open circuited. 3 Exposure lamp Inverter SLG board • Check if the connectors of the exposure lamp and inverter are disconnected. • Check the SLG board if the connector pin CN21 is disconnected or the harness is short circuited or open circuited. • Check if the conductor pattern on the SLG board is short circuited or open circuited.