Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi CC30 — Toshiba e-Studio 283

Code: CC30

Description: Stack processing motor abnormality: The stack processing motor is not rotating normally or the stack delivery belt is not moving normally. [MJ-1022] Paddle motor abnormality: The paddle motor is not rotating normally or the swing guide is not moving normally. [MJ-1025]
Remedy: MJ-1022 (Stack processing motor abnormality) [Procedure 1] Is the tension of the drive belt normal? NO Loosen the adjustment screw to adjust its tension. YES Does the bushing attached to the returning roller shaft smoothly move up and down? NO Apply grease on the cut-out part of the front side frame where the bushing contacts. YES Is the spring of the returning roller detached? YES Attach the spring. NO Is the wiring between the finisher controller PC board and stack delivery motor (M2) correct? NO Correct the wiring. YES Is the stack delivery lever home position sensor (S8) working properly? NO Replace the sensor. YES 1) Replacing the stack processing motor. 2) Replace the finisher controller PC board.