Mã lỗi C150, C160 — Toshiba e-Studio 3005AC

Code: C150, C160

Description: [C150] PFP upper drawer tray abnormality [C160] PFP lower drawer tray abnormality
Causes: Tray-up motor PFP board PFC board Tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check: FS-03-278, FS-03-280) Yes 2 No • Check if the connector of the tray-up motor is disconnected. (J967, J961, CN244) • Check if any of the connectors CN241 and CN244 on the PFP board is disconnected. • Check if the connector CN459, J700 on the PFC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP board and PFC board are short circuited or open circuited. 2 Is the tray-up sensor working? (Perform the input check: FS-03- [F1]ON/[5]/[A], FS-03- [F1]ON/[5]/[E]) Yes 3 No • Check if the connector of the sensor is disconnected. (CN246, J960, J965, J966, J970, J972) • Check if any of the connectors CN241 and CN246 on the PFP board is disconnected. • Check if the connector CN459, J700 on the PFC board is disconnected. • Check if the slit reaches the sensor. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP board and PFC board are short circuited or open circuited. 3 PFC board • Check if the conductor pattern on the PFC board is short circuited or open circuited.

← Xem tất cả mã lỗi Toshiba e-Studio 3005AC

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie