Code: C3E1

Description: Drum/cleaner/charger unit replacement (old-new) detection abnormality
Causes: Drum old/new detection switches Drum TBU motor LGC board Harness
Remedy: 1 Check if the old/new detection pusher of the drum cleaner unit is being ejected. Yes 4 No 2 2 Check if the harness of the drum old/new detection switch in the drum cleaner unit is open circuited. Yes 3 No Replace the harness. 3 Is the drum old/new detection switch of the drum cleaner unit normal? Yes 4 No Replace the drum old/new detection switch. 4 Check if the drum old/new detection pusher is moved to the escape position while the coupling of the drum cleaner unit is rotated by hand. (Is a driving in the old/new detection pusher section transmitted?) Yes 3 No Correct the drum old/new detection pusher so that it is moved to the escape position. 5 Check that the coupling of the drum TBU drive unit is driven properly. Yes Correct the engagement of the couplings in the drum TBU drive unit and the drum cleaner unit. 9 No 6 6 Check that the drum TBU drive motor rotates properly. (Input check: FS-03-101/151) Yes 9 No 7 7 Check that the connector of the drum TBU drive motor is connected properly. (CN327, J651) Yes 9 No 8 8 Check if the harness of the drum TBU drive motor is open circuited. Yes 9 No Replace the drum TBU drive motor. 9 Check that the connector of the LGC board (CN313, CN327) is connected properly. Yes 11 No Reconnect the connector. 10 Is the harness of the LGC board normal? Yes 11 No Replace the harness. 11 Is the LGC board normal? Replace the LGC board.

← Xem tất cả mã lỗi Toshiba e-Studio 3005AC

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie