Mã lỗi CB30 — Toshiba e-Studio 3005AC

Code: CB30

Description: Movable tray shift motor (M1) abnormality, Movable tray paper top detection error MJ-1042
Causes: Movable tray shift motor (M1) Stack top detection solenoid (SOL1) Stack top detection sensor-1 (S1) Stack top detection sensor-2 (S2 Movable tray lower limit sensor (S14) A locking signal is detected after the specified time *while the movable tray is moving. * A locking signal is not monitored from the start driving the motor until the specified time has passed. The stack top position of paper is not detected after the movable tray shift motor (M1) is driven in the specified time when the movable tray is moved up. The lower limit position of the stack top of paper is not detected after the movable tray shift motor (M1) has been driven in the specified time during the initial movement of the movable tray. The turning OFF of the movable tray lower limit sensor (S14) is not detected when the movable tray is moved from a point where this sensor is turned ON to one point where this sensor is turned OFF after the movable tray shift motor (M1) has been driven in the specified time.
Remedy: Movable tray shift motor (M1) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Movable tray lower limit sensor (S14) abnormality Measure the voltage on TP17 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V„b5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity among the connector terminals is normal. If electricity is not conducted, replace the connectors. (Finisher control PC board (FIN): CN4, CN10) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the motor, sensors and connectors, exchange the finisher control PC board (FIN). Stack top detection solenoid (SOL1) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the solenoid. Stack top detection sensor-1 (S1) abnormality Measure the voltage on TP11 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V„b5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Stack top detection sensor-2 (S2) abnormality Measure the voltage on TP20 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V„b5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Finisher control PC board (FIN): CN3) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the solenoid, sensors and connector, exchange the finisher control PC board (FIN).

← Xem tất cả mã lỗi Toshiba e-Studio 3005AC

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie