Code: E030
Description: Power-ON jam
Causes: Sensor in the jamming area Refer to the table below. LGC board
Remedy: Sensor in the jamming area • Sensor check (Refer to the table below) • Connector check • Harness check LGC board • Board check • Connector check • Harness check
Registration area Jam access cover Registration sensor FS-03-[ALL]OFF/[9]/[A] Paper clinging detection sensor FS-03-[ALL]OFF/[9]/[E] Registration pass sensor FS-03-[ALL]OFF/[9]/[F] Feed sensor FS-03-[ALL]OFF/[9]/[B] Exit area Fuser cover Exit sensor FS-03-[ALL]OFF/[9]/[C] ADU ADU ADU entrance sensor FS-03-[ALL]OFF/[9]/[G] ADU exit sensor FS-03-[ALL]OFF/[9]/[H] Bypass feed unit Side cover 2nd drawer feed sensor FS-03-[F3]ON/[4]/[D] LCF LCF side cover LCF transport sensor FS-03-[F1]ON/[9]/[F] PFP PFP side cover PFP upper drawer feed sensor FS-03-[F3]ON/[0]/[C] PFP lower drawer feed sensor FS-03-[F3]ON/[0]/[D] Bridge unit Bridge unit Bridge unit transport sensor-1 (Entrance sensor) FS-03-[ALL]OFF/[0]/[A] Bridge unit transport sensor-2 (Exit sensor) FS-03-[ALL]OFF/[0]/[B] Finisher Finisher door Sensors in the finisher
Registration area Jam access cover Registration sensor FS-03-[ALL]OFF/[9]/[A] Paper clinging detection sensor FS-03-[ALL]OFF/[9]/[E] Registration pass sensor FS-03-[ALL]OFF/[9]/[F] Feed sensor FS-03-[ALL]OFF/[9]/[B] Exit area Fuser cover Exit sensor FS-03-[ALL]OFF/[9]/[C] ADU ADU ADU entrance sensor FS-03-[ALL]OFF/[9]/[G] ADU exit sensor FS-03-[ALL]OFF/[9]/[H] Bypass feed unit Side cover 2nd drawer feed sensor FS-03-[F3]ON/[4]/[D] LCF LCF side cover LCF transport sensor FS-03-[F1]ON/[9]/[F] PFP PFP side cover PFP upper drawer feed sensor FS-03-[F3]ON/[0]/[C] PFP lower drawer feed sensor FS-03-[F3]ON/[0]/[D] Bridge unit Bridge unit Bridge unit transport sensor-1 (Entrance sensor) FS-03-[ALL]OFF/[0]/[A] Bridge unit transport sensor-2 (Exit sensor) FS-03-[ALL]OFF/[0]/[B] Finisher Finisher door Sensors in the finisher