Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E930 — Toshiba e-Studio 3008A

Code: E930

Description: Jam at the bridge unit transport sensor-2: The trailing edge of the paper does not reach the bridge unit transport sensor-2 after its leading edge has reached the bridge unit transport sensor-1.
Causes: Bridge unit transport sensor-2 (exit sensor) LGC board
Remedy: Bridge unit transport sensor-2 (exit sensor) • Sensor check (Perform the input check: FS-03-[ALL]OFF[0]/[B]) • Connector check (CN311, J607, J802) • Harness check LGC board • Board check • Connector check (CN311) • Harness check Bridge unit • Does the transport roller of the bridge unit work when the main motor is rotated? (Perform the output check: FS-03-101/151) • Check the drive system of the equipment and bridge unit. • Check if the rollers in exit section, bridge unit and pressure spring are worn out.

← Xem tất cả mã lỗi Toshiba e-Studio 3008A