Mã lỗi C130, C140 — Toshiba e-Studio 3008AG

Code: C130, C140

Description: [C130] 1st drawer tray is abnormal [C140] 2nd drawer tray is abnormal
Causes: LGC board Upper tray-up motor Lower tray-up motor 1st drawer tray-up sensor 2nd drawer tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check in the test mode: FS-03- 242, FS-03-243) Yes 2 No 1. Check if the connector of the upper tray-up motor is disconnected. 2. Check if the connector of the lower tray-up motor is disconnected (J677). 3. Check if the connector CN318 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor pattern on the LGC board is short circuited or open circuited. 2 Is the tray-up sensor working? (Perform the input check in the test mode: FS-03- [ALL]OFF/[0]/[E], FS-03- [F3]ON/[4]/[E]) Yes 3 No 1. Check if the connector of the sensor is disconnected. 2. Check if the connector CN316 on the LGC board is disconnected. 3. Check if the slit reaches the sensor. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor pattern on the LGC board is short circuited or open circuited. 3 LGC board 1. Check if the conductor pattern on the LGC board is short circuited or open circuited. 2. Replace the LGC board.