Remedy: 1 Is the LCF jam access cover open? Yes Remove the paper if there is any, then close the cover. No 2 2 Is the LCF jam access cover opening/closing switch working? (Perform the input check in the test mode: FS-03- [F1]ON/[9]/[A]) Yes 3 No • Check if the connector of the LCF jam access cover opening/closing switch is disconnected. • Check if either of the connectors CN1 or CN7 on the LCF board is disconnected. • Check if the connector CN315 on the LGC board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. • Replace the LCF jam access cover opening/closing switch. • Replace the LCF board. • Replace the LGC board. 3 Replacing board • Replace the LCF board. • Replace the LGC board.