Code: C452
Description: Abnormal thermopile temperature difference
(Heater lamp abnormality after abnormality judgment)
(Heater lamp abnormality after abnormality judgment)
Causes: Power supply unit Thermopile LGC board
Remedy: Power supply and fuser unit • Check if the fuser unit is installed properly. • Check if foreign matter or paper in the fuser unit is plugging up the monitoring opening of the thermopile. • Check if there is any stain on sensor area of the fuser belt thermopile. • Check if the heater lamp is open circuited. • Check if the connector of the heater lamp is disconnected. • Check if the thermistor is open circuited. • Check if the connectors of the power supply unit (power supply unit AC output connector CN408, CN409 and LGC/IF connector CN404, CN405) are disconnected. • Check if the power supply unit is broken. Thermopile • Check if foreign matter is plugging up the thermopile. • Check if the thermopile is installed properly. • Check if the harnesses are open circuited. LGC board • Check if the connectors CN333, CN345 and CN361 are disconnected. • Check if the conductor pattern on the LGC board is short circuited or open circuited. Status counter 1. Turn the power ON while [0] and [8] are pressed simultaneously. 2. Key in “2002”, then press the [START] button. 3. Reset the displayed current status counter value "38", "39", "41", "42", "48", "49", "50" or "51" to "0", then press [OK] or [INTERRUPT]. (The error C451 or C452 is cleared.) 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal status