Code: CE41
Description: Image quality TRC control test pattern abnormality: The image quality TRC control test pattern is not printed normally.
Causes: LGC board SYS board
Remedy: 1 Change the setting of the image quality TRC control to "Disabled". Set the values of 08-2600 and 08-8103 to "0". 2 2 Output several number of sheets of the image quality control test pattern (04-270) and the list print ([9][START]->101), and check the pattern of each color. Is the image normal? YES 3 NO • Check if process units and developer units are properly installed. • Check if there is any scattered toner or developer material around the LED head, clean it if there is any. • Correct the problem by referring to "Troubleshooting for the Image". "8.5 Troubleshooting for the Image" 3 Change the setting of the image quality TRC control to "Enabled". Set the values of 08-2600 and 08-8103 to "1". 4 4 Perform the automatic gamma adjustment. If the adjustment is normally finished, this is the end of the procedure. If the error CE41 still occurs, proceed to step 5. 5 4.Check if the harness between the connector CN128 on the SYS board and the connector CN350 on the LGC board is disconnected or open circuited. Correct if so. 6 6 6.Check if the conductor patterns on the SYS board and the LGC board are short circuited or open circuited. 7 7 7.If no abnormality is found in steps 5 to 6 above, replace the IMG board. 8 8 8.Perform automatic gamma adjustment. If the adjustment is normally finished, this is the end of the procedure. If the error CE41 still occurs, proceed to step 9. 9 Reinstall the removed SYS board and then replace the LGC board. Perform automatic gamma adjustment after the board is replaced.