Code: EA2C
Description: Paper transport jam in the Finisher (Entrance path - sub-path sensor) [MJ-1036]
Causes:
Remedy: 1st transport motor (M8) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. 2nd transport motor (M4) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Entrance path sensor (S19) abnormality Measure the voltage on TP86 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Sub-path sensor (S8) abnormality Measure the voltage on TP85 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Stationary tray full detection sensor (S11) abnormality Measure the voltage on TP26 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Finisher control PC board (FIN): CN6, CN10, CN14, CN22) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the sensor and the connector, replace the finisher control PC board (FIN).