Description: Paddle motor abnormality: The paddle motor does not rotate properly.
Causes: MJ-1101 Paddle motor Finisher control PC board MJ-1106 Paddle motor (M8) Finisher control PC board
Remedy: MJ-1101 Paddle Rotate the paddle. Fix any mechanical problem. Paddle motor Check the connectors and harnesses between the paddle motor (M8) and the finisher control PC board (CN6). MJ-1106 Paddle IRotate the paddle. Fix any mechanical problem. Paddle motor (M8) Check if the connector (CN22) on the finisher controller PC board is disconnected from the paddle motor (M3) and the harnesses are open circuited. Correct if so.