Code: E000
Description: Fixing unit startup defect
Causes: The detected temperature of the main thermistor does not rise above 5 deg C (temperature at power ON is 0 deg C) within one second of the heater being energised. Cause: Main thermistor broken wire, fixer heater broken wire, DC controller PCB defect
Remedy: - Check the connector of the low-voltage power supply PCB. - Replace the fixing film unit. - Replace the DC controller PCB.