Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi CA10 — Toshiba e-Studio 306SD

Code: CA10

Description: Laser optical unit related service call Polygonal motor abnormality: The polygonal motor is not rotating normally.
Causes: LGC board Laser optical unit
Remedy: 1 Is the polygonal motor rotating? Yes 1. Check if the conductor pattern on the LGC board is short circuited or open circuited. 2. Replace the LGC board. 3. Replace the laser optical unit. No 1. Check if the connector of the harness is disconnected between LGC board (CN314) and the laser optical unit. Reconnect it securely if so. Even if the connector is not apparently disconnected, it may be connected loosely. Therefore check carefully that it is secure. 2. Check if the harness is open circuited and the connector pin is disconnected. 3. Check if the conductor pattern on the LGC board is short circuited or open circuited. 4. Replace the laser optical unit. 5. Replace the LGC board.

← Xem tất cả mã lỗi Toshiba e-Studio 306SD